Noise filter
Filters clog with use. The manual lists how often to change it.
Filters clog with use. The manual lists how often to change it.
Replaces WH12X10310
No heat after a full cycle usually means a burned-out element.
A dead display or random faults can come from the control board.
Drive parts wear out: a machine that fills but won't spin or agitate often points here.
A dead display or random faults can come from the control board.
1Noise filterWH41X10301
2ThermistorWH12X10351
3Control boardWH12X10544
4ActuatorWH43X10059Part numbers come from the Sears PartsDirect parts list for the GE GFWS1505D0MS (view the list), checked November 16, 2026. Amazon buttons open a search for the part number; we may earn a commission.
Front-load: on the door frame or the door rim. Top-load: under the lid or on the back of the control panel.