Thermistor
Reads or limits temperature. A failed one can stop the heat or let it run too hot.
Reads or limits temperature. A failed one can stop the heat or let it run too hot.
Water left in the drum after a cycle usually points to the pump.
Leaks or mould on the door boot mean it's time for a new one.
Door, lid and control switches stop a cycle when they fail.
Door, lid and control switches stop a cycle when they fail.
Cracked or leaking hoses should be replaced before they burst.
Racks, shelves and bins made to fit this model.
1Thermistor6322FR2046C
2Tub-to-pump hose4738ER1002A
3Outer tub gasket4036ER4001F
4Door lockEBF61315802Part numbers come from the Sears PartsDirect parts list for the LG WM3500CW/00 (view the list), checked November 16, 2026. Amazon buttons open a search for the part number; we may earn a commission.
Front-load: on the door frame or the door rim. Top-load: under the lid or on the back of the control panel.